🔧 PROBE_WAKEUP_TIME_MS 30 for BIQU probes (#28153)

This commit is contained in:
David Buezas
2025-11-10 06:43:37 +01:00
committed by GitHub
parent 88a4e55945
commit a420e3c155
2 changed files with 15 additions and 4 deletions

View File

@@ -3687,4 +3687,10 @@
#define FTM_BUFFER_SIZE 128
#endif
#define FTM_BUFFER_MASK (FTM_BUFFER_SIZE - 1u)
#if ANY(BIQU_MICROPROBE_V1, BIQU_MICROPROBE_V2)
#ifndef PROBE_WAKEUP_TIME_MS
#define PROBE_WAKEUP_TIME_MS 30
#define PROBE_WAKEUP_TIME_WARNING 1
#endif
#endif
#endif

View File

@@ -724,6 +724,10 @@
#warning "BIQU MicroProbe V2 detect signal requires a strong pull-up. Some processors have weak internal pull-up capabilities, so we recommended connecting MicroProbe SIGNAL / GND to Z-MIN / Z-STOP instead of the dedicated PROBE port. (Define NO_MICROPROBE_WARNING to suppress this warning.)"
#endif
#if PROBE_WAKEUP_TIME_WARNING
#warning "PROBE_WAKEUP_TIME_MS has been set to the default 30ms."
#endif
//
// Warn users of potential endstop/DIAG pin conflicts to prevent homing issues when not using sensorless homing
//
@@ -943,6 +947,9 @@
#if ENABLED(FTM_HOME_AND_PROBE)
#if ANY(BIQU_MICROPROBE_V1, BIQU_MICROPROBE_V2)
#warning "Let us know if you experience any issues with BIQU Microprobe and FT_MOTION."
#if PROBE_WAKEUP_TIME_MS <= 25
#warning "A PROBE_WAKEUP_TIME_MS over 25 ms is recommended with FT_MOTION and BIQU_MICROPROBE_V1 or BIQU_MICROPROBE_V2."
#endif
#endif
#if PROBE_WAKEUP_TIME_MS < 30
#warning "A PROBE_WAKEUP_TIME_MS over 30 ms is recommended with FT_MOTION."
@@ -973,8 +980,6 @@
/**
* Smooth Linear Advance with Mixing Extruder, S-Curve Acceleration
*/
#if ENABLED(SMOOTH_LIN_ADVANCE)
#if ENABLED(MIXING_EXTRUDER)
#warning "SMOOTH_LIN_ADVANCE with MIXING_EXTRUDER is untested. Use with caution."
#endif
#if ALL(SMOOTH_LIN_ADVANCE, MIXING_EXTRUDER)
#warning "SMOOTH_LIN_ADVANCE with MIXING_EXTRUDER is untested. Use with caution."
#endif