Add Unit of Measurement for MiFlora Fertility and Fix MiJia BT battery to percentage (#466)

* adds unit for MiFlora fertility value

* fixes MijiaBT battery unit from V to percentage
This commit is contained in:
kanttti
2019-09-29 22:21:19 +03:00
committed by Florian
parent 07e32847fa
commit e4de45f219

View File

@@ -111,7 +111,7 @@ void MiFloraDiscovery(char * mac){
char * MiFlorasensor[MiFloraparametersCount][8] = {
{"sensor", "MiFlora-lux", mac, "illuminance","{{ value_json.lux | is_defined }}","", "", "lu"} ,
{"sensor", "MiFlora-tem", mac,"temperature","{{ value_json.tem | is_defined }}","", "", "°C"} ,
{"sensor", "MiFlora-fer", mac,"","{{ value_json.fer | is_defined }}","", "", ""} ,
{"sensor", "MiFlora-fer", mac,"","{{ value_json.fer | is_defined }}","", "", "µS/cm"} ,
{"sensor", "MiFlora-moi", mac,"","{{ value_json.moi | is_defined }}","", "", "%"}
//component type,name,availability topic,device class,value template,payload on, payload off, unit of measurement
};
@@ -139,7 +139,7 @@ void MiJiaDiscovery(char * mac){
#define MiJiaparametersCount 3
trc(F("MiJiaDiscovery"));
char * MiJiasensor[MiJiaparametersCount][8] = {
{"sensor", "MiJia-batt", mac, "battery","{{ value_json.batt | is_defined }}","", "", "V"} ,
{"sensor", "MiJia-batt", mac, "battery","{{ value_json.batt | is_defined }}","", "", "%"} ,
{"sensor", "MiJia-tem", mac,"temperature","{{ value_json.tem | is_defined }}","", "", "°C"} ,
{"sensor", "MiJia-hum", mac,"humidity","{{ value_json.hum | is_defined }}","", "", "%"}
//component type,name,availability topic,device class,value template,payload on, payload off, unit of measurement