What you see in a tab of main work area is called a patch. In other programming languages a XOD patch corresponds to a single source file or module.

Until now youve created single-patch programs and the patch was given name main automatically for you. Creating a whole project on a single patch would become messy once number of nodes and links will pass some limit. In many cases it is a good idea to split complex patches into several that are easier to understand and change.

Furthermore, you can reuse a patch several times in your project with slightly different parameters and in such way avoid nodes duplication.

The mechanism which lets you use one patches as nodes on other patches is called patch nodes.

In this chapter were going to build simple watering station for two plants. The idea is to water a plat if its soil became too dry and constantly show current soil measurements on text LCD screen.

Single plant station on a single patch

To start lets build a device that will work with a single plant. Well use single patch main as in previous chapters.

Create new project water-station and wire up your circuit:

Single plant circuit

Now make a following patch to control the device:

Single plant patch

Make sure to properly set port values for all hardware nodes.

You may noticed it is very similar to previously implemented smart light project. All things weve changed is the sensor and the actuator. Moisture sensor replaced the light sensor and the pump replaced the LED.

Upload the program to your board and test the device. Put the sensor into a glass of water and take it out. See how the relay reacts. Observe the text shown on LCD.

Lets improve the program a bit and add pretty formatting to the messages. So that instead of "0.42" the LCD would show something like "Cactus: 42%". We achieve this by adding two nodes. First one to-percent would convert number from sensor to a string like "42%". Second one concat would concatenate a constant prefix "Cactus: " with the percent string:

Single plant patch with percents

Extracting plant logic to a separate patch

So far, so good. Now consider we want to extend the device to handle two plants at once. We have another sensor, yet another relay, and pump. What we want to share is LCD. Each plants message should be shown on its own line.

The very staightforward way to do it would be duplicate most of nodes related to reading data, comparing it and formatting the result. But it would quickly became unmanagable and error prone. Changes in one place would always require mirroring the changes in other places by hand.

Patch nodes to the rescue. What do we have in common between different plants and what differs? The logic is common, but the name of the plant, its watering threshold value differs. Ports used to connect the sensor and the relay differs too. So these things should be provided as parameters to our patch.

What the patch could output to the outside world? It could be a status message string and a pulse that denotes that update is completed.

Create new patch with File → New Patch and name it plant. Look at Project Browser youll see that plant patch has appeared next to our main.

First of all were going to define its inputs and outputs. Expand xod/patch-nodes in Project Browser and notice nodes with names like input-xxx and output-xxx. They are called terminals and define patch input and output pins. Place few inputs and outputs according to what weve planned to parametrize:

Plant patch terminals

Now give the terminal nodes informative labels so that we can remember which one means what:

Plant patch terminals with labels

Switch back to the main patch. And try to add two nodes of our newly created type plant:

Patch nodes

Were going to use these two nodes to manage plants and move existing logic to the shared plant patch. Lets do it.

XOD T0D0 Currently there is no cut/copy/paste in XOD. Yes, thats a pain. Well implement it in future versions. If you would like to give the feature more priority we welcome you to share your opinion on our forum.

Here is final main patch:

Main patch for two plants

And the plant patch:

Plant patch

Wire up the circuit:

Single plant circuit

Set parameters for your plants with Inspector. Then upload the program and see how both plants are served simultaneously with a single patch.

Whats next

Our quick tutorial is almost completed. The last thing to learn is what you can do to build arbitrary projects with arbitrary hardware. See Complex Projects chapter to know more.