When a saved RF configuration exists in NVS, loadFromStorage() was loading
the config but not calling iRFReceiver.enable(), which meant initCC1101()
was never invoked during boot. This caused the CC1101 to not receive signals
until the user manually toggled the RF receiver via the WebUI.
This fix adds a reinitReceiver parameter to loadFromStorage() that controls
whether to disable/enable the receiver after loading config. By default it's
true (for boot-time initialization), but loadFromMessage() passes false to
avoid double initialization when loading config from MQTT messages.
Fixes#2264
Co-authored-by: Florian <1technophile@users.noreply.github.com>
Co-authored-by: Odyno <odyno@users.noreply.github.com>
🤖 Generated with [Claude Code](https://claude.ai/code)
Co-authored-by: claude[bot] <41898282+claude[bot]@users.noreply.github.com>
- Introduced RFConfiguration class to encapsulate RF settings and operations.
- Replaced direct usage of RFConfig structure with iRFConfig instance across multiple files.
- Updated frequency handling in actuatorSomfy, gatewayPilight, gatewayRF, and gatewayRF2 to use iRFConfig.
- Modified webUI to interact with iRFConfig for RF settings management.
- Removed deprecated RFConfig structure and related functions.
- Enhanced JSON handling for RF configuration loading and saving.
- Improved logging for RF configuration operations.